Roof and Gutter Maintenance
Keep a safe roof over your head – with a little help from Mitre 10.
Roofing problems are a problem in most homes at some stage or other, and very often with just a little know-how and assistance from Mitre I0 the problem can be easily solved. Here we cover several of the most common roofing maintenance areas.
Plan ahead
Since roof work can expose the house to prevailing weather it is best to carefully plan what the job will entail in time, sequence of work, and materials. With a carefully detailed plan you will be in a position to purchase all the required materials prior to commencement and have a work schedule to guide your time.
Tools for the Job
METAL ROOF, SPOUTING, DOWN-PIPES
TILE ROOF
To make the job easier
In roof plumbing joins, flashing laps and spouting laps are overlaid and lapped in the direction of the flow of water from the top downwards (Fig. 2).
In some maintenance instances pop rivets will need to be removed. This is done by drilling the pop rivet out with a suitable size drill bit or using a medium sized flat bladed screw driver and hammer and knocking off the head of the rivets. Paint will not adhere to silicone so remove all external traces of silicone with a rag moistened with mineral turpentine.
Spouting
Step I: Investigating
Firstly find out whether the existing spouting profile is available, be carefulthough as what may look the same could in fact be marginally different in size and profile to your existing. It is best to take either a piece of the spouting or one of the spouting clips to your Mitre I0 store. If you are able to match the exact profile then you will not need to remove and replace the spouting clips, unless of course the existing spouting has no fall to the drainage point. Prior to accessing your roof, wrap some cloth around the top of your ladder ends so the spouting does not get scratched. Then place a piece of timber inside the spouting where the ladder is going to be placed so the pressure of weight does not distort the line of the spouting (Fig. 3). Spouting may be available to order at some Mitre 10 stores.
Step 2: Removing existing
First task is to release the pop rivets which are holding the joins, corners and perhaps the spouting brackets and spouting together. It may be necessary to cut the spouting to facilitate removal, this is done with a hacksaw or tin snips, do not use an angle grinder. The spouting will have been fixed to the fascia board by spouting brackets and nails. To remove the spouting bend the clips at the outer upper lip of the spouting bracket upwards (Fig. 4), then rotate the spouting off the bracket. Remove the spouting clips with your pinchbar.
Step 3: Setting out
To create water flow to the down-pipe or outlet the spouting needs to be placed out of level, the rate of fall should be around 15-25mm per I0 metres. To create a straight line run a string line out from one end to the other, stretch it tight and check that it has the correct amount of fall with a spirit level (Fig. 5). Place the spouting brackets at one metre spacings using the string line as a guide to the horizontal position. Pre-formed internal and external corners can be purchased for most spouting profiles, however for certain profiles and colours these may need to be made to order, so allow time in your ordering for this. Make a note of where the down pipes are located, and cut and fit the down pipe pops into the spouting prior to putting the spouting up (Fig. 6). Silicone seal between the pop flange and the spouting, press the pop into place and the pop rivet the flanges to the base of the spouting.
Step 4: Fitting the spouting
Commence laying the spouting from the lowest (down pipe end) point, this way the join laps will be layered so the collected water runs over the top of the joins and not into them. Measure along the fascia board for the length of spouting required, add to the length an allowance for a 20mm lap join into adjoining spouting and also the internal or external corners. Cut the spouting to length using your hacksaw or tin snips (do not use an angle grinder). Silicone and join the pre-formed corner to the spouting with pop rivets, use 4 pop rivets per join. Squeeze some silicone around the inside of the overlapping end of any joining spouting. Place the spouting onto the fascia clips and position with the 20mm lap into the adjoining spouting. Press the spouting firmly into place, bend over the restraining tags on the spouting brackets and drill and pop rivet the joins. Clean any excess silicone off the face of the spouting and smooth out any silicone buildup inside the join.
Down pipes
Step 1: Removal
Remove down pipe clips, and release any pop rivets at joins or the down pipe pop. One section of down pipe should be able to be slid down over the other to free it.
Step 2: Fitting down pipe
One end of the down pipe is larger in dimension than the other, this is the top section in all instances and allows one piece to fit inside the other and to a certain degree helps length adjustment. Join lap should be a minimum of 40mm. Silicone is not used on the down pipe joins. Commence installation at the top with the spouting, joining and adjusting the length of the eaves bends. Measure, cut and fit the remaining lengths of down pipe. Place a downpipe clip over each join, and secure to the wall with screws or clouts (Fig. 7).
Loose ridge & hip capping tiles
Step 1: Removing & cleaning
Take a bucket up onto the roof with you so all debris can be cleaned as it accumulates. To save breakage of tiles carefully tap the mortar joint between the tile and capping tile with a cold chisel. Once the tile is loose remove the old mortar from all surfaces.
Step 2: Bedding joint
Mix up enough mortar for the job, at the rate of 4 sand, I cement, I limil. Add colour pigment to the mix if needed, this is to be in strict accordance with manufacturers instructions as too much will weaken the bed joint. Add water to create a thick creamy substance. Place some of the mixture in a bucket and take it up on the roof. Mark the outer edge line of the capping tile onto the roof tiles, and with the brickies trowel spread a bed of mortar about 50mm x 50mm along the inside of the marked line. Carefully press the ridge cap into the mortar bed until the correct height has been obtained (Fig. 8), progressively overlap and lay the rest of the tiles. Clean excess mortar off along the edge line of the tiles to leave a full clean bed of mortar.
Chimney flashing
Chimney flashing generally lasts pretty well, but where it needs replacing use the existing flashing as a pattern to either bend up your own from I6 guage zinc alum or galvanized iron, or get some bent for you through your local Mitre I0 store. (Some stores may not offer this service.) The various components of a typical chimney flashing system and how they fit around the chimney are shown in Fig. 9. There is only one correct way to proceed here, and that is in the sequence mentioned in ‘To make the job easier’. The flow of all water must be over the top of all laps, so laying of the flashing must commence at the lower point of the area to be flashed. First install base flashing, ‘ A’ the top lip being pressed into the brick course by 10mm and a bead of silicone to seal this lip to the brick course. Next install side flashings ‘ B’ and ‘ C’, silicone seal the lip into the brick course and silicone and pop rivet the tray overlap to the base flashing. Finally the top rear flashing ‘ D’ is installed, this flashing tucks under the roof tiles and also the top lip fits into the brick course and is silicone sealed. The tray extends out over the top of the side flashings and is silicone sealed and pop riveted for a weather tight seal. Clean off all excess silicone before it dries.
Metal roofs – Loose sheets
Corrugated iron sheets fixed down with roofing nails will inevitably become loose over time. The easiest surest way of securing this problem is to remove the offending nail and replace with roofing screws. These are a 50mm long hexagonal headed screw with a rubber washer (Fig. I0). Using a matching driver bit in a cordless drill insert the screw into the hole left by the nail and tighten down securely. In no circumstance put nails or screws in the lower section of the corrugation.